The short version
- Book the blowout for early to mid October. The median first 32°F freeze at MSP is October 18, and one year in ten it comes by October 1.
- Winterizing is three steps: shut off the water, drain the system, and blow out the lines with compressed air.
- The backflow preventer sits above ground and freezes first. It is also the most expensive part to replace.
- Air volume clears the lines, not pressure. Manufacturer guidance keeps pressure at or below 50 psi for poly pipe and 80 psi for PVC.
- Minnesota requires testable backflow assemblies to be tested every year, and a rain or moisture sensor on systems installed after July 1, 2003.
When to do it
The deadline is set by frost. Using the 1991–2020 climate normals for Minneapolis–St. Paul:
| At MSP airport | 1 year in 10, by | Median date | 9 years in 10, by |
|---|---|---|---|
| First 32°F freeze | October 1 | October 18 | October 31 |
| First 28°F hard freeze | October 15 | October 29 | November 11 |
A light frost will not hurt buried pipe, but the backflow preventer is brass, above ground, and full of water. One night in the mid-20s can crack it. The safe window is the first three weeks of October: late enough that the lawn no longer needs water, early enough to beat the hard freeze.
Some years are forgiving. In 2026 the first freeze at MSP did not arrive until November 6, one of the latest on record. Some are not, and every contractor's schedule fills in the same two weeks, so book in September. If a cold night arrives before your appointment, shut off the irrigation supply inside the house and wrap the backflow preventer in a blanket or insulation.
What a proper blowout involves
The University of Minnesota's turfgrass program describes winterizing as shutting off the supply, draining the system, and blowing out the remaining water with compressed air, and says the blowout should be done by a certified irrigation professional. The steps:
- Shut off the irrigation supply at the valve inside the house or at the meter.
- Drain the supply line between that valve and the backflow preventer.
- Connect a compressor downstream of the backflow preventer, never through it. Compressed air can damage its seals.
- Run each zone from the controller, one at a time, until the heads blow mist and then air. Repeat short cycles instead of one long one, because air running through dry pipe builds heat.
- Leave the backflow preventer's ball valves and test cocks at 45 degrees, half open, so trapped water can expand without cracking the body.
- Set the controller to off or rain mode so it keeps its programming without running the valves.
Pressure, volume, and why a garage compressor struggles
What clears a sprinkler line is the volume of air moving through it, measured in cubic feet per minute. Pressure only needs to be high enough to keep that air moving. Hunter Industries, one of the largest irrigation manufacturers, tells installers not to exceed 50 psi on flexible polyethylene pipe or 80 psi on rigid PVC.
As the university's guidance notes, a home compressor can reach those pressures but usually cannot supply the volume. It fills its tank, releases a short burst, and stops to refill, which pushes water to the low spots in the line and leaves it there. Turning the pressure up to compensate is how fittings and heads get broken. A contractor's tow-behind compressor delivers many times the volume at a lower, regulated pressure.
Two safety rules apply to anyone doing this: wear eye protection, and never stand over a head or valve box while a zone is under air.
Minnesota rules worth knowing
- Annual backflow testing. The Minnesota Plumbing Code requires testable backflow prevention assemblies to be tested when installed and at least once a year by a certified tester. The tester tags the device and sends the record to the city or water supplier. Lakeville, Rosemount, and Apple Valley each spell out the annual test on their irrigation pages.
- Rain sensors. State law requires automatic irrigation systems installed after July 1, 2003 to have technology that stops the system when there has been enough rain. If your controller runs in a downpour, the sensor is missing or dead.
- Permits. New irrigation systems and backflow replacements need a plumbing permit in most south-metro cities.
- Watering schedules. Most cities here use odd/even or time-of-day limits in season. They are listed on our city pages.
What happens if you skip it
Water expands about nine percent when it freezes. In an irrigation system it has nowhere to go. The usual damage, in order of how often we see it in spring:
- A cracked backflow preventer, which sprays the side of the house at start-up.
- Split valve bodies and manifolds in the valve boxes.
- Cracked sprinkler heads and swing joints at the low points of each zone.
- Split pipe, usually found as a wet spot or a zone with no pressure.
One cracked backflow device costs several times what a blowout does.
Spring start-up
Wait until the frost is out of the ground, usually mid to late April. Then:
- Close the drains and the test cocks on the backflow preventer.
- Open the supply valve slowly. Filling the main line too fast causes water hammer, which breaks fittings.
- Run each zone and walk it. Look for heads that do not rise, geysers, and dry arcs.
- Straighten and adjust heads so they water the lawn and not the street.
- Have the backflow assembly tested.
- Set the schedule for spring, not July. Lawns need far less water in May.
We handle start-up, mid-season checks, and fall blowouts as a program. See irrigation service, or new irrigation systems if you are adding one.
Common questions
When should I blow out my sprinklers in Minnesota?
Can I winterize my own sprinkler system?
What air pressure is safe for blowing out sprinklers?
Does a sprinkler system need a rain sensor in Minnesota?
- Minnesota DNR: 1991–2020 freeze date probabilities, Minneapolis–St. Paul airport
- Minnesota DNR: freeze and frost dates
- University of Minnesota Turfgrass Science: properly preparing irrigation systems for winter
- Hunter Industries: winterizing your irrigation system
- Minnesota Statutes 103G.298: landscape irrigation systems
- Minnesota Plumbing Code, Minn. Rules 4714.0603: backflow prevention
- City of Lakeville: lawn irrigation handout
- City of Rosemount: lawn irrigation systems